Walk-In BOD Incubator (Bio-Oxygen Demand) are used to maintain temperature for test tissue culture growth, storage of bacterial cultures and incubation where high degree of constant temperature accuracy is required. Sailab BOD Incubators provide with accurate conditions and uniformity throughout the chamber.

WALK-IN BOD INCUBATOR

  • Pre-fabricated doubled walled modular panels with PUF insulation
  • Inside Stainless Steel and Outside Mild Steel Powder Coated OR Stainless Steel
  • Floor panels having extra reinforcement to sustain the movement and sample load inside the chamber
  • Interior illumination for working area
  • Multi pane vacuum sealed observation glass window
  • Heavy-duty door hinges and latches to maintain a secure and uniform seal
  • Racks & trays – Stainless Steel with adjustable height
  • 65 mm Port Hole with rubber seal to insert sensors for validation purpose
  • Interior illumination for working area
  • U shaped S.S. Nichrome wire air heaters
  • Auto change over to stand by cooling system in case of failure of regular cooling system or vice versa
  • Compressor with CFC Free R 134 A / R 404 (Eco Friendly) refrigerant having state of art by-pass system for continuous run of compressor
  • Plc control system with touch screen display coloured screen – 5.7” HMI with Ethernet
  • Web based online monitoring
  • Complete with IQ, OQ, PQ, Documents, Operations and Maintenance manuals
  • Works on 23V AC single phase 50Hz
  • 21 CFR Part 11 compliance window based communication software for data management
  • Stand by refrigeration system
  • Scanner 8 point temperature complete with sensors and printer interface and data storage facility Door Access Security system
  • Mobile Alert system
  • 80 Col. Dot Matrix printers along with Stainless Steel stand
  • Standard Model(S) : Inside S.S. 304 with mirror polish & outside mild steel powder coated
  • GMP Model(G) : Inside S.S. 304 with mirror polish & outside with S.S. 304 matt buff
  • Temperature Range : 5°C to 60°C
  • Temperature Accuracy : ± 0.2°C
  • Temp Uniformity : ± 2.0°C
ModelsCapacityDimensions in meters Max No. of trays
Ltrsinernal
WDH
TB 40 S/G 4000212.18
TB 60 S/G 600021.5212
TB 80 S/G 800022224
TB 125 S/G 1250022.52.528
TB 187 S/G 187502.532.536
TB 232 S/G 232503.132.540
TB 275 S/G 275003.43.22.555
TB 320 S/G 320003.73.52.566
TB 450 S/G 450003.93.9384
TB 500 S/G 500003.855.22.5100
TB 800 S/G 800006.452.5200
TB 960 S/G968006.15.293240